PVC:
Polyvinyl Chloride Flexible Membrane Liners for Concrete Precast
Products
Typical Physical Property Values of our Chemical Resistant Liner
Film
Download a print friendly PDF of this Spec Sheet
|
Gauge:
30 mil Hand: 5S Form#: -98004.0
Operating Temperature Range: 0 F to 140 F
|
Property |
Unit |
Test Method |
Required |
Value |
Durometer |
Shore A |
ASTM D-1240 |
|
77 |
Specific Gravity |
g/cc |
ASTM D-792 |
|
1.27 |
Tensile Strength |
PSI |
ASTM D-882 |
|
MD 2150
TD 1840
|
Elongation |
% |
ASTM D-882 |
|
MD 280
TD 310 |
Elmendorf Tear |
g/mil |
|
|
MD over 300
TD over 300 |
Cold Impact |
Degrees F |
ASTM D-1790 |
|
passed at-20 |
Hydrostatic Resistance
(lbs/sq in) |
|
ASTM D-751 |
100 min. |
115 |
Resistance to
Soil Burial
|
|
ASTM D-3083 |
TBreaking Factor
+/- 5%
Elongation at Break +/- 20%
Modulus at 100% +/- 20% Elongation
|
Pass
Pass
Pass
|
Shrinkage |
|
ASTM D-1204 |
Less than 5% MD |
-1.5 |