PVC: Polyvinyl Chloride Flexible Membrane Liners for Concrete Precast Products
Typical Physical Property Values of our Chemical Resistant Liner Film
Download a print friendly PDF of this Spec Sheet

Gauge: 30 mil    Hand: 5S    Form#: -98004.0    Operating Temperature Range: 0 F to 140 F
Property Unit Test Method Required Value
Durometer Shore A ASTM D-1240   77
Specific Gravity g/cc ASTM D-792   1.27
Tensile Strength PSI ASTM D-882  

MD 2150
TD 1840

Elongation % ASTM D-882   MD 280
TD 310
Elmendorf Tear g/mil     MD over 300
TD over 300
Cold Impact Degrees F ASTM D-1790   passed at-20
Hydrostatic Resistance
(lbs/sq in)
  ASTM D-751 100 min. 115

Resistance to
Soil Burial

  ASTM D-3083

TBreaking Factor
+/- 5%

Elongation at Break +/- 20%

Modulus at 100% +/- 20% Elongation

Pass

 

Pass

Pass

Shrinkage   ASTM D-1204 Less than 5% MD -1.5