Welcome to our Downloads page-

Here you will find versions of our printed brochures in PDF format. You will need the
Adobe Acrobat Reader to view these files.

Need our References?  Click here to download a PDF of our professional reference call sheet.

Need a Credit Application?  Click here to download

See below for sample text for specifing our product in your next project. You may download a MS Word document or cut and paste the text directly from the bottom of this page.

And check back later for downloadable CAD drawings and other text descriptions/ specifications of our products for easy integration into your engineering projects.

 

PDF Versions of our print material -

Saving the Environment One Backyard at a Time Brochure

The Universal Liner, Flexible Membrane & Breakout barrier Brochure

Sample Engineering Notes Specifications (MS Word Document)

The Universal Liner Brochure

Product Specifications Sheet

Liner Fax-Back Order Form

Nondisclosure Form

 

Examples of Engineering Notes indicating Miller Environmental Products-

Example 1

Example 2

 

Sample verbiage for our products on your next engineering project -

Special Instructions for tight tank installation:

1. The tight tank shall be lined, on the inside and outside, with double lining on the tank
bottom, to provide additional protection in case of tank failure.

2. The liner will be a polyvinyl chloride (PVC) flexible membrane liner 30 mil in thickness,
and will be field installed with a representative of Miller Environmental Products, Inc.
(Liner manufacturer) present.

3. The tank, with liners, shall be installed onto a level (and compacted) bed of sand,
with a suitable rubber (or equivalent) mat not less than 1/4" in thickness to be placed
between the sand and the external liner.

4. The liner will be field welded (seamed) using proven chemical fusion or taping techniques. As
well as appropriate 6" stainless steel bands and other fasteners (if necessary) to
physically hold the liner in place.

5. The liner will be fabricated to provide and effective seal around the inlet pipe and the
manhole riser.

6. A plaque or sign shall be installed, to instruct the septage hauler as to specific
techniques to avoid damaging the liner during routine pumping. The plaque shall read:
"This tank is lined with a PVC Membrane. To avoid puncture, do not use sharp objects within
the tank. Miller Environmental Products, Inc. (508) 378-3800"

 

 