The following information is provided to help engineers & installers specify and order Streamline Kits from Miller Environmental Corp.
Pumps:
Use the Streamline Program to specify your pump. Enter project specific data into the Streamline Design Form, Calculate the project and then select a pump from the Streamline Pump Curve Facility.
Control Panels :
To specify control panels indicate either simplex or duplex pump arrangement and how you want the float switch configuration to work as shown in the example below:
Pump Arrangement - Duplex
Float Switch Configuration:
Pump Off - Turn Pumps Off
Lead Pump On - Powers Lead Pump Alternating Pumps Between Doses
Lag Pump On - Powers Lag Pump
Alarm On - Powers Control Panel Alarm
Miller Environmental Corp. will provide the proper control panel and float switches with your order based on this information and the Streamline pump specification.
Distribution Network Piping:
Once the distribution network design has been completed using the Streamline program, the Streamline Design Form and Calculations will provide Miller Environmental Corp. all the information they need to build a pressure distribution network kit including predrilled distribution laterals and manifold piping and fittings.
It is recommended that the approved pressure distribution layout be provided to Miller Environmental Corp. to provide us with a blueprint of the actual system layout. The preferred format for this is PDF files sent via email to info@millerenvironmentalinc.com; contact Miller Environmental Corp. to transmit this information in other formats.
Pipe, Fittings, Valves & Accessory Onsite Wastewater Products:
Miller Environmental Corp. carries pipe, pipe fittings, valves and a full line of accessory products for use with pressure distribution systems including:
Float Switches
Float Switch Brackets
Float Switch Cable Weights
Pump Guide Rail Systems
Effluent Filters
Air Release Valves
Orifice Shields
Male Pump Adapters
Check Valves
True Unions
Ball Valves
Gate Valves
Cast Iron or Plastic Valve Boxes
Cast Iron or Plastic Manhole Frames & Covers
Access Doors & Hatches
Manway Access Risers
Polyethylene Pump Chambers & Septic Tanks
Filter Fabric
Breakout Barrier Liners
All above products should be specified as Miller Environmental Corp.; for example, if the project requires 36 orifice shields, they should be specified on the plans as ...
"Provide 36-each Miller Environmental Corp. Orifice Shields to be installed as shown on plan"
Please specify H-10, H-20 or other structural requirements that may be project specific.
Click here to download the Streamline User Guide (PDF 1.5 mb)
|